background

IM-CSC Cell Monitoring Unit CB01-D06

CELL MONITORING UNIT

IM-CSC precisely monitors cell voltages and temperatures to ensure safe operation of the battery and allows passive cell balancing with 300 mA. The balancing modules are connected to each other through isolated communication.

Key Features
  • Voltage monitoring for up to 56 cells (7-14 cells per balancing unit)
  • Cell temperature monitoring with 6 NTC temperature sensors
  • Passive balancing
  • CAN interface
  • Wake-up function with contact detection input

Power
Operating Voltage Range9 - 32 VDC
Nominal Operating Voltage12 VDC / 24 VDC
Power Consumption~ 60 mA (12 VDC)
Interface
CommunicationCAN 2.0A/B
Supported Communication Speed500 kBit/s
Other Features
Wake-Up1 x Contact detection input
Cell Count7 - 56 cells (minimum 7 cells required for operating voltage)
Cell Count per Balancing Unit7 - 14 cells
Cell Voltage Measurement Range0 - 5 V
Cell Balancing TopologyPassive
Cell Balancing Current300mA (at 3.9V cell voltage)
Cell Voltage Sampling Time50 ms
Cell Voltage Accuracy±0.4 mV (at 25°C)
Temperature Measurement Range-40°C ~ 120°C
Temperature Measurement Accuracy±1°C
Temperature Sensor Channels24 (6 temperature sensors per balancing unit)
Operating Temperature-40°C ~ 85°C
Mechanical Details
Dimensions113.73 x 272.87 x 19.25 mm
ConnectorsJAE MX34024NF1, JAE MX34003NF1
Compatible ConnectorsJAE MX34024SF1, JAE MX34003SF1
Weight196 g